Description
Product Description
Eaton Tripp Lite series switched PDU, 1PH, 2U, NEMA L6-30 input, 15ft cord, 5.5kW, 24A, 208V, 14 outlets (8) C13 (6) C19
Eaton Tripp Lite series switched PDU, 1PH, 2U, NEMA L6-30 input, 15ft cord, 5.5kW, 24A, 208V, 14 outlets (8) C13 (6) C19 14 Switched outlets (8 C13, 6 C19) and 15ft./4.5m NEMA L6-30P input cord Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability 5.5kW 208/230V Switched 24A PDU, 2U rackmount, Reversible housing 2-year limited warranty (Worldwide) Pre-installed WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature Reports voltage, frequency and load level; Front-panel digital current meter
14 Switched outlets (8 C13, 6 C19) and 15ft./4.5m NEMA L6-30P input cord Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability 5.5kW 208/230V Switched 24A PDU, 2U rackmount, Reversible housing 2-year limited warranty (Worldwide) Pre-installed WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature Reports voltage, frequency and load level; Front-panel digital current meter
Power Extension Cord, Right-Angle C13 to C14 PDU Style – 10A, 250V, 18 AWG, 2 ft. (0.61 m), Black
Key Features
- 14 Switched outlets (8 C13, 6 C19) and 15ft./4.5m NEMA L6-30P input cord
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
- Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability
- 5.5kW 208/230V Switched 24A PDU, 2U rackmount, Reversible housing
- 2-year limited warranty (Worldwide)
- Pre-installed WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature
- Reports voltage, frequency and load level; Front-panel digital current meter
- Power distribution units for IT equipment
- Power distribution FAQs
Specifications
| Official Eaton Specifications | |
|---|---|
| Product Name | Eaton Tripp Lite series switched PDU |
| Catalog Number | PDUMH30HV19NET |
| UPC | 037332153753 |
| Product Length/Depth | 12.5 in |
| Product Height | 3.5 in |
| Product Width | 17.5 in |
| Product Weight | 13.7 lb |
| Warranty | 2 year limited |
| Compliances | FCC Class A RoHS |
| Certifications | NOM CSA certified UL 60950-1 |
| Global Catalog | PDUMH30HV19NET |
| Product Type | Switched PDU |
| Form factor | 2U |
| Package contents | PDUMH30HV19NET with attached L6-30P input power cord Installed WEBCARDLX network interface Installable 2U mounting brackets Configuration cable User manual |
| Operating Temperature | 32° to 104°F (0° to 40°C) |
| Mounting direction | Horizontal |
| Material | Metal |
| Input connection | NEMA L6-30P |
| Cord length | 15 ft |
| Amperage Rating | 24A |
| Electric current – max | 24 |
| Phase | Single-phase |
| Frequency rating | 50/60 Hz |
| Number of Outputs C13 | 8 |
| Number of Outputs C19 | 6 |
| Features | Flex Center |
| SNMP | Yes |
| Front Panel LCD Display | 2 digit meter and pushbutton display toggle switch reports output current in amps in 3 loading segments, Bank 1 (C13 outlets #1-8), Bank 2 (C19 outlets #9-14) and Banks 1&2 combined (Outlets #1-14) |
| Output Receptacles | C13 C19 |
| Grounding options | Grounding lug |
| LED indicators | 14 power availability LEDs confirm power off/on status for each built-in outlet; Two additional LEDs identify which bank the visual current meter is reporting (Bank 1, Bank 2 or Banks 1&2 combined) |
| Minimum required rack depth | 16 in |
| Network ports | RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. |
| Overload protection | Three 20A circuit breakers; Breaker 1 (Bank 1 C13 outlets #1-8), Breaker 2 (Bank 2 C19 outlets #9-11), Breaker 3 (Bank 2 C19 outlets #12-14) |
| Recommended electrical service | Single-phase 30A 208/230V service |
| Output Receptacles Details | Compatible with Eaton Tripp Lite Power Cords |
| Receptacles | Each outlet is individually controllable via remote interface C13 C19 |
| Input Cord Length | 15 ft |
| Switch configuration | Pushbutton near the two digit current meter toggles reporting of output amps on Bank 1, Bank 2 and Total PDU output (Banks 1 & 2 combined) |
| TAA Compliance | Yes |
| Communications Cable | Micro-USB- to-USB A configuration/console Access cable |
| Amperage Rating Details | Agency de-rated to 24A continuous |
| Operating elevation | 0-10000 ft. (0-3000 m) |
| Operating temperature range | 32° to 104°F (0° to 40°C) |
| Output nominal voltage | 208/230V |
| Relative humidity | 5% to 95% non-condensing |
| Form Factors Supported | 2U rackmount |
| Output Capacity Details | 5.5kW (230V), 5kW (208V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet |
| Output Capacity (kW) | 5.5 |
| Storage temperature | -22° to 122°F (-30° to 50°C) |
| Network Speed | 10 Mbps 100 Mbps (Fast Ethernet) |
| PowerAlert Software | LX Platform Interface: PowerAlert Device Manager |
| SNMP Compatibility | Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems |
| PDU Plug Type | L6-30P |
| PDU Type | Switched |
| PDU Input Voltage | 208 |
| High Availability PDU Features | Auto probe monitoring and reboot (included) Auto load shedding |
| PDU Form Factor | Horizontal (2U) |
| Total Outlets | 14 |
Warranty
2 year limited
Downloads & Official Resources
Product Information
| Brand | Eaton / Tripp Lite |
|---|---|
| Manufacturer Part Number | PDUMH30HV19NET |
| SKU | PDUMH30HV19NET |
| UPC / GTIN | 037332153753 |




Reviews
There are no reviews yet.